ER316
Class: ER316
AWS: A5.9
Conforms to Certification: AWS A5.9 | ASME SFA A5.9
Weld Process Used for Mig: (GMAW) and Submerged Arc (SAW)
AWS Chemical Composition Requirements
C = 0.08 max
Cr = 18.0 – 20.0
Ni = 11.0 – 14.0
Mo = 2.0 – 3.0
Mn = 1.0 – 2.5
Si = 0.30 – 0.65
P = 0.03 max
S = 0.03 max
Cu = 0.75 max
Available Sizes |
|
Diameter X Spool Sizes | Diameter X Coil Sizes |
.025 x 2#, 10#, 25# | 1/16 x 60# & mill coil |
.030 x 2#, 10#, 25#, 30#, 33# | 5/64 x 60# & mill coil |
.035 x 2#, 10#, 25#, 30#, 33# | 3/32 x 60# & mill coil |
.045 x 2#, 10#, 25#, 30#, 33# | 1/8 x 60# & mill coil |
1/16 x 10#, 25#, 30#, 33# | 3/16 x 60# & mill coil |
5/32 x 60# & mill coil |
Application
ER316 is recommended for welding AISI 316 stainless steel applications when high creep strength at elevated temperatures where resistance to pitting by corrosive liquids is needed.
Deposited Chemical Composition % (Typical) | ||
C = 0.05 | Mo = 2.25 | P = 0.012 |
Cr = 19.25 | Mn = 1.70 | S = 0.010 |
Ni = 11.25 | Si = 0.40 |
Mechanical Properties (R.T.) | |
Yield Strength | 59,000psi |
Tensile Strength | 88,000psi |
Elongation | 40% |
Reduction of Area | 60% |
Deposited All Weld Metal Properties
Data is typical for ER316 weld metal deposited by Mig using Argon + 2% oxygen as the shielding gas. Data on sub-arc is not presented, as sub-arc is dependent on the type of flux used.
Recommended Welding Parameters |
||||||
GMAW “Mig Process” | Reversed Polarity | |||||
Wire Diameter | Wire Feed | Amps | Volts | Shielding Gas | Gas CFH | |
Short Arc Welding | .030 | 13-26 | 40-120 | 16-20 | Argon+2% O2 | 25 |
.035 | 13-26 | 60-140 | 16-22 | Argon+2% O2 | 25 | |
Spray Arc Welding | .035 | 20-39 | 140-220 | 24-29 | Argon+2% O2 | 38 |
.045 | 16-30 | 160-260 | 25-30 | Argon+2% O2 | 38 | |
1/16 | 10-16 | 230-350 | 27-31 | Argon+2% O2 | 38 |
Other shielding Gases may be used for Mig welding. Shielding gases are chosen taking Quality, Cost, and Operability into consideration
Recommended Welding Parameters |
||
SAW “Submerged Arc Welding Process” | Reversed Polarity Suggested | |
Wire Diameter | Amps | Volts |
3/32 | 250-450 | 28-32 |
1/8 | 300-500 | 29-34 |
5/32 | 400-600 | 30-35 |
3/16 | 500-700 | 30-35 |
Both Agglomerated and fused fluxes can be used for submerged arc welding.
Note: The chemical composition of the flux mainly affects the chemistry of the weld metal and consequently its corrosion resistance and Mechanical properties.