ERCuNi
Class: ERCuNi
AWS: A5.7
Conforms to Certification: AWS A5.7 | ASME SFA A5.7
Weld Process: GMAW, ASAW and Oxy-Fuel Welding Processes
AWS Chemical Composition Requirements | |
Cu = Remainder | Mn = 1.0 max |
Fe = 0.40 – 0.75 | Si = 0.25 max |
Ni = 29.0 – 32.0 | P = 0.02 |
Pb = 0.02 | Ti = 0.20 – 0.50 |
Other = 0.50 max |
Available Sizes
.035 x 36
.045 x 36
1/16 x 36
3/32 x 36
1/8 x 36
Application
ERCuNi (NA67) is used for gas metal and gas tungsten arc welding. Can also be used by oxy-fuel welding of 70/30, 80/20, and 90/10 copper nickel alloys. A barrier layer of nickel alloy 610 is recommended prior to overlaying steel with GMAW weld process.
Deposited Chemical Composition % (Typical) | ||
Ni = 31.0 | Mn = 0.75 | P = 0.006 |
Cu = Balance | Si = 0.10 | Ti = 0.35 |
Fe = 0.55 |
Deposited All Weld Metal Properties % (AW) | |
Tensile Strength | 54,000 psi |
Yield Strength | 21,500 psi |
Elongation | 32% |
Deposited Charpy-V-Notch Impact Properties %
Not applicable
Recommended Welding Parameters for TIG Nickel Alloys |
||||
Process | Diameter of Wire | Voltage (V) | Amperage (A) | Gas |
Tig | .035 inches x 36 | 12-15 | 60-90 | 100% Argon |
.045 inches x 36 | 13-16 | 80-110 | 100% Argon | |
1/16 inches x 36 | 14-18 | 90-130 | 100% Argon | |
3/32 inches x 36 | 15-20 | 120-175 | 100% Argon | |
1/8 inches x 36 | 15-20 | 150-220 | 100% Argon |
Note: Other shielding Gases may be used for Tig welding. Shielding gases are chosen taking Quality, cost, and Operability into consideration.
Note: Both agglomerated and fused fluxes can be used for submerged arc welding.
Note: The chemical composition of the flux mainly affects the chemistry of the weld metal and consequently its corrosion resistance and mechanical properties.