ERNiFe-CI
Class: ERNiFe-CI
AWS: A5.15
Conforms to Certification: AWS A5.15 | ASME SFA A5.15
Weld Process: GTAW Welding Processes
AWS Chemical Composition Requirements | |
C = 0.1 max | Si = 0.20 max |
Mn = 0.5 – 1.5 | P = 0.02 max |
Fe = Remainder | Ni = 55.0 min |
S = 0.02 max | Other = 1.0 max |
Cu = 0.20 max |
Available Sizes
.035 x 36
.045 x 36
1/16 x 36
3/32 x 36
1/8 x 36
Application
ERNiFe-CI, Nickel Alloy 55 is used welding gray, ductile and Ni-resist cast irons to wrought alloys. It is also noted for high sulfur, phosphorus or lubricant-contaminated castings.
Deposited Chemical Composition % (Typical) | ||
C = 0.05 | S = 0.003 | Ni = 55.51 |
Mn = 0.25 | Cu = 0.10 | Fe = Balance |
Si = 0.106 | P = 0.007 |
Deposited All Weld Metal Properties % (AW) | |
Tensile Strength | 89,500 psi |
Yield Strength | 62,000 psi |
Elongation | 35% |
Deposited Charpy-V-Notch Impact Properties %
Not applicable
Recommended Welding Parameters for TIG, MIG, and SAW Welding of Nickel Alloys |
||||
Process | Diameter of Wire | Voltage (V) | Amperage (A) | Gas |
Tig | .035 inches x 36 | 12 – 15 | 60 – 90 | 100% Argon |
.045 inches x 36 | 13 – 16 | 80 – 110 | 100% Argon | |
1/16 inches x 36 | 14 – 18 | 90 – 130 | 100% Argon | |
3/32 inches x 36 | 15 – 20 | 120 – 175 | 100% Argon | |
1/8 inches x 36 | 15 – 20 | 150 – 220 | 100% Argon |
Note: Other shielding Gases may be used for Tig welding. Shielding gases are chosen taking Quality, cost, and Operability into consideration.
Note: Both agglomerated and fused fluxes can be used for submerged arc welding.
Note: The chemical composition of the flux mainly affects the chemistry of the weld metal and consequently its corrosion resistance and mechanical properties.